Dental Autoclave

Product Overview

 

This commercial-grade steam sterilizer complies with EN 13060 Class B standards, engineered for dental clinics, multi-chair practices, and ambulatory surgical centers requiring validated decontamination of complex, cannulated, and porous loads. The unit utilizes a fractional pre-vacuum air-removal system combined with a rapid pulsed steam injection architecture, ensuring steam penetration into hollow instrument lumens (such as dental handpieces, endodontic files, and surgical drills) prior to the sterilization phase. Constructed with a stamp-formed seamless SUS304 stainless steel chamber and governed by a microprocessor-based PLC, the system sustains precise thermal and barometric thresholds across every validated sterilization cycle.

 

 
  • Tabletop Sterilizer
    The sterilizing procedure is automatically controlled, it is not necessary to be supervised, and used conveniently.
    Steam-water inner circulation system:no steam discharge, and the...
    read more
  • Benchtop Autoclave Sterilizer
    Benchtop Autoclave Sterilizer
    Microcomputer control
    LCD display and touch buttons
    Automatic protection function
    read more
 
Working Principle

The sterilization cycle executes across five fully monitored, automated phases:

Fractional Pre-Vacuum:

The high-capacity diaphragm vacuum pump executes 3 consecutive pulse evacuations, drawing chamber pressure down to -0.082 MPa to extract trapped air from complex instrument geometries and porous wraps.

01

Heating & Steam Injection:

Saturated steam generated by the built-in independent steam generator is injected into the chamber, rapidly elevating internal temperature to operational setpoints.

02

Sterilization Hold:

The system maintains a stable thermal threshold—selectable between 134°C (2.1 bar) for 4 to 18 minutes or 121°C (1.1 bar) for 20 to 30 minutes—ensuring microbial inactivation.

03

Post-Vacuum Drying:

A deep vacuum phase extracts residual moisture from instrument loads. Filtered ambient air (0.2 um medical-grade HEPA) breaks the vacuum, yielding dry sterile loads with a residual moisture level of <0.2% for wrapped instruments.

04

Cycle Validation:

Internal sensors log real-time pressure, temperature, and cycle duration data, transmitting records via USB flash drive or the integrated thermal strip printer.

05

 

Key Features

 

Fractional Pre-Vacuum Technology: Achieves complete air removal, satisfying the stringent penetration requirements for hollow Type B and Type A dental instruments per EN 13060.


Integrated TDS Water Quality Sensor: Automatically measures feed water conductivity (<15 uS/cm required); halts cycle initiation if water impurity exceeds the safety threshold, preventing mineral scale buildup and heating element burnout.


Independent Steam Generator: External high-efficiency steam generator produces dry saturated steam on demand, accelerating cycle turnaround times and reducing chamber thermal fatigue.


Traceability & Data Export: Built-in thermal printer and USB port log full cycle parameters (pressure curves, holding time, temperature) for regulatory compliance and clinic record-keeping.


Multi-Stage Safety Interlocks: Features a mechanical pressure-actuated door lock, electronic microswitch sensor, and over-temperature/over-pressure relief valves to prevent accidental chamber opening during operation.

 

Tabletop Sterilizer

 

Configuration & Components

Chamber Assembly: Seamless stamp-formed SUS304 stainless steel with an electropolished interior surface, rated for a maximum working pressure of 2.4 bar (hydrostatically tested at 3.6 bar).


Vacuum Pump: Dual-head diaphragm vacuum pump engineered for continuous commercial operation with low noise emission (<50 dB).


Hydraulic Circuit: Industrial-grade solenoid valves and high-temperature brass fittings resistant to demineralized water corrosion.


Control Interface: Industrial 7-inch color touchscreen (HMI) displaying real-time pressure/temperature curves, water tank levels, and error diagnostics.


Water Reservoirs: Independent, easily accessible top-mounted fresh water tank (4L) and wastewater tank (4L) with integrated internal filter screens and cleaning ports.

 

Technical Specifications

 

Parameter

Specification Details

Sterilization Standard

EN 13060 Class B (Compliant with ISO 17665)

Chamber Dimensions

Diameter 247 mm x Depth 450 mm (18L Model)

Overall Dimensions

Width 480 mm x Depth 600 mm x Height 410 mm

Net Weight

48 kg (18L Configuration)

Rated Voltage / Frequency

220V - 240V, 50/60 Hz (Optional 110V)

Power Consumption

1800 W (Peak during heating phase)

Operating Temperatures

121°C (1.1 bar) / 134°C (2.1 bar)

Test Cycles Supported

Bowie & Dick Test, Helix Test, Vacuum Leak Test

Water Consumption per Cycle

Approx. 0.3L to 0.5L (Demineralized water)

Data Storage Interface

USB Flash Drive Port & Integrated Thermal Printer

 

 
 
Applications

General Dental Practices:

Sterilization of examination mirrors, scalers, forceps, and metallic hand instruments.

 

Endodontics & Oral Surgery:

Processing complex root canal files, ultrasonic tips, surgical cassettes, and low/high-speed handpieces that demand lumen air removal.

Implantology:

High-temperature sterilization of surgical kits, implant drivers, and titanium prosthetic components.

Dental Teaching Labs:

Sterilization cycles adapted for student training kits and multi-user clinic environments.

 

Model Selection & Configuration Options

 

Model

Chamber Volume

External Dimensions (W x D x H)

Recommended Facility Scale

DA-16L

16 Liters

480 x 550 x 410 mm

Small clinic / Single-chair setup

DA-18L

18 Liters

480 x 600 x 410 mm

Standard multi-chair practice (2-4 chairs)

DA-22L

22 Liters

480 x 670 x 410 mm

Busy dental clinic / Small surgical center

DA-29L

29 Liters

530 x 720 x 440 mm

Large dental hospital / High-turnover department

 

 

Manufacturing & Quality Control

Chamber Hydrostatic Testing: Every pressure vessel undergoes hydro-testing at 1.5x maximum working pressure (3.6 bar) prior to final assembly to verify structural containment.


Welding Process: Fully automated robotic TIG welding is utilized for chamber seams, eliminating human inconsistency and preventing micro-fissures.


Burn-In Testing: Completed units undergo a mandatory 48-hour continuous operational burn-in test running 10 full sterilization cycles under rated load prior to packing.


Electrical Safety Inspection: Automated testing verifies grounding continuity, dielectric withstand voltage (1500V AC), and insulation resistance per IEC 61010-1 standards.


Quality Framework: Manufactured in strict accordance with ISO 13485 quality management requirements.

Benchtop Autoclave Sterilizer

 

Customization & Integration

 

 

OEM/ODM Support:

Custom color powder-coating on side panels, bespoke user interface splash screens, and customized packaging cartons for channel partners.

 

Accessory Integration:

Options to bundle ultrasonic cleaners, water distillation units, and external barcode label printers configured for sterile-batch tracking.

 

Electrical Compliance:

Direct configuration for regional plug types and dedicated regional power grids.

 

 

 

Frequently Asked Questions

 

 

Q: What water purity level is required for this autoclave, and what happens if untreated tap water is used?

A: The system requires demineralized or distilled water with a conductivity of <15 uS/cm (Total Dissolved Solids <10 ppm). Using untreated tap water introduces calcium and magnesium minerals that rapidly precipitate onto heating elements and block internal valves, triggering a TDS error alarm and voiding the chamber warranty.

Q: Does this autoclave pass the standard Bowie & Dick and Helix tests required by health authorities?

A: Yes. The unit includes pre-programmed test routines specifically configured to execute the EN 867-5 Helix test (for hollow instruments) and the ISO 11140-5 Bowie & Dick test (for steam penetration in porous loads), generating compliant verification records.

Q: What is the average duration of a standard 134°C wrapped instrument cycle?

A: For an 18L chamber loaded to rated capacity, a complete 134°C universal cycle (including pre-vacuum air removal, 4-minute sterilization hold, and vacuum drying phase) takes approximately 35 to 45 minutes, depending on the total load weight and initial temperature.

Q: How is cycle data retrieved for hospital or clinic sterilization logs?

A: Data is logged digitally in real-time. Operators can export records via the built-in USB flash drive port in PDF format, or print hard copies directly using the integrated thermal strip printer located on the front control panel.

Q: What is the warranty coverage for the pressure chamber and core electronic components?

A: We provide a 3-year warranty on the stainless steel chamber assembly against structural failure or corrosion perforation, and a 2-year warranty on core electrical components (PLC controller, vacuum pump, and valves) under normal operating conditions and maintenance schedules.

Q: Can this autoclave be integrated into existing clinic water supply systems for automatic filling?

A: Yes. Standard models operate via internal manual-fill reservoirs (4L). However, selected models support an optional automatic water-feed and direct-drain plumbing kit, allowing direct connection to an external RO (Reverse Osmosis) water purification system and wastewater line.

We're well-known as one of the leading dental autoclave manufacturers and suppliers in China. With abundant experience, we warmly welcome you to buy high quality dental autoclave for sale here from our factory. For price consultation, contact us.